Optical Instruments

You see: 1-16 / 16 items
Show per page
Sort:
  • NOVA HLX-220 Portable Rebound Leeb Hardness Tester

    NOVA HLX-210 Portable Rebound Leeb Hardness Tester

    Measuring range: 170-960 HLD

    Measurement direction: 360° (upside down)

    Hardness cales: HL, HB, HRB, HRC, HRA, HV, HS

    Data memory: 500 test results 

    Data output: USB 2.0

    Display: LCD dotmatrix display

    Power: 6V Ni-Mh battery

    Operating time: ~150 hours (without display lighting)

    Overall dimensions: 212x80x32 mm

    Weight: ~500 g

  • NOVA HLX-310 Portable, Rebound Leeb Hardness Tester

    NOVA HLX-310 Portable, Rebound Leeb Hardness Tester

    Measuring range: 170-960 HLD

    Measurement direction: 360° (upside down)

    Hardness scales: HL, HB, HRB, HRC, HRA, HV, HS

    Data memory: 48-600 result group

    Data output: USB 2.0

    Display: 128x64 LCD display

    Power: 3V (2x AA battery)

    Time of operation: ~100 hours (without display backlight)

    Overall dimensions: 128x73x30 mm

    Weight: ~260g

  • NOVA Ultra - Ultrasonic (UCI) Hardness Tester

    NOVA Ultra - Ultrasonic (UCI) Hardness Tester

    Measurement procedure: UCI 50N (10N is optional)

    Hardness scales: HRC, HRB, HV, HB, HL, MPa

    Measurement ranges: HV: 230~940; HRC: 20~70; HB: 25~650; MPa: 370~1740

    Accuracy: ±3%HV; ±2%HRC; ±3%HB

    Measurement direction: 360° (upside down)

    Data memory: depends on the size of memory card inserted

    Data output: USB output, optional data processing software

    Output: colourful, back-lit display

    Power: 3x AA battery/accumulator (kb. 5-8 hours of operation time)

    Overall dimension: 160x75x30 mm

    Weight: 0,3 kg (without probe)

  • NOVA HLD-20 Portable Leeb Rebound Hardness Tester

    NOVA HLD-20 Portable Leeb Rebound Hardness Tester

    Rebound probe type: internal, type D probe

    Hardness scales: HRB, HRC, HB, HS, HV, HLD

    Accuracy: ±6HLD (±0,8% at HLD=800)

    Data output: USB, RS-232

    Maximum hardness of specimen: 900 HV

    Data memory: 250 data group

    Power: 2x1.5V AA battery

    Operation temperature: -10°C ... 50°C

    Overall dimensions: 146x65x36 mm

    Weight: 130 g

  • NOVA HLD-30 Portable Leeb Rebound Hardness Tester

    NOVA HLD-30 Portable Leeb Rebound Hardness Tester

    Rebound probe type: internal, type D probe

    Hardness scales: HRB, HRC, HB, HS, HV, HLD

    Accuracy: ±6HLD (±0,8% at HLD=800)

    Data output: USB, RS-232

    Maximum surface roughness of specimen: 1.6µ (Ra)

    Maximum hardness of specimen: 940 HV

    Specimen's minimum radius of curvature: Rmin= 50mm (convex/concave)

    Minimal thickness of specimen coupled: 5 mm

    Minimal hardened crust thickness: 0.8 mm

    Data memory: 250 data group

    Power: 3x AA battery

    Operation temperature: 0°C ... 40°C

    Overall dimensions: 146x65x36 mm

    Weight: 130 g

  • NOVA AB-HBR2 Rockwell Hardness Clamp Testers

    NOVA AB-HBR2 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 50x50 mm

  • NOVA AB-HBR42 Rockwell Hardness Clamp Testers

    NOVA AB-HBR42 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 100x75 mm

  • NOVA AB-HBR84 Rockwell Hardness Clamp Testers

    NOVA AB-HBR84 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 200x100 mm

  • NOVA AB-HR43 Rockwell Hardness Clamp Testers

    NOVA AB-HR43 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 50x50 mm

  • NOVA AB-HR84 Rockwell Hardness Clamp Testers

    NOVA AB-HR84 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 200x100 mm

  • NOVA AB-HR810 Rockwell Hardness Clamp Testers

    NOVA AB-HR810 Rockwell Hardness Clamp Testers

    Rockwell scales: HRA, HRB, HRC, HRD

    Preload: 10 kg

    Applied forces: 60kg, 100kg, 150 kg Rockwell; 

    Resolution: 0,5HR

    Accuracy: ±1,5 HR

    Conversion: HV, HB

    Max. jaw distance: 200x250 mm

  • Aquila Touch - Touchscreen Vickers Hardness Tester

    Aquila Touch - Touchscreen Vickers Hardness Tester

    Measuring range: 8 HV ~ 2967 HV

    Applied forces: 0.5 kgf (4,9N); 1 kgf (9,8N); 2 kgf (19,6N); 2,5 kgf (24,5N); 3 kgf (29,4N); 5 kgf (49N); 10 kgf (98N); 20 kgf (196N); 30 kgf (294N)

    Resolution: 1 HV

    Conversion scales: HRC, HV, HBS, HBW, HK, HRA, HRD, HR15N, HR30N, HR45N, HS, HRF, HR15T, HR30T, HR45T, HRB

    Dwelling time: 1-60 sec

    Measurement sequence: automatic

    Data output: RS-232, Bluetooth (optional)

    Display: 5.2” LCD touchscreen

    Power: 230V - 50 Hz

    Overall dimensions (LxWxH): 533x225x580 mm

    Weight: ~55 kg

  • Bison Touch Closed Loop Touchscreen Hardness Tester

    Bison Touch - Closed Loop Touchscreen Hardness Tester

    • Measurement range: 8 HBW ~ 650 HBW
    • Applied forces: 62,5kgf (612,9N); 100kgf (980,7N); 125kgf (1226N); 187,5kgf (1839N); 250kgf (2452N); 500kgf (4903N); 750kgf (7355N); 1000kgf (9807N); 1500kgf (14710N); 3000kgf (29420N)
    • Conversion scales: HRC, HV, HBS, HBW, HK, HRA, HRD, HR15N, HR30N, HR45N, HS, HRF, HR15T, HR30T, HR45T, HRB
    • Dwelling time: 1-60 sec
    • Measuring sequence: automatic
    • Data output: Bluetooth, RS-232 (optional)
    • Display: touchscreen
    • Power: 230V - 50 Hz
    • Overall dimensions (LxWxH)): 545x235x755 mm
    • Weight: ~160 kg
  • Aquila DiAm Vickers Hardness Tester with Digital Microscope

    Aquila DiAm Vickers Hardness Tester with Digital Microscope

    Measuring range: 8 HV ~ 2900 HV

    Test load: 1kgf (9,8N); 3kgf (29,4N); 5kgf (49,0N); 10kgf (98,0N); 20kgf (196N); 30kgf (294N)

    Conversion scales: HRA, HRB, HRC, HED, HRF, HV, HK, HBW, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T

    Duration time: 0-60 sec

    Method of testing force applied: automatic

    Data output: RS-232, built-in printer

    Display: 5,0” LCD display

    Power: 230V - 50 Hz

    Overall dimensions (LxWxH): 520x190x650 mm

    Weight: ~40 kg

  • Bullseye CCD Camera System for Brinell Measurement Analysis

    Bullseye B CCD Camera System for Brinell Measurement Analysis

    CCD camera system for Brinell hardness and indentation analysis. Have your Brinell hardness tests conducted and analysed with variable statistical functions offered by the Bison Bullseye measurement analysis software. The digital analysis significantly reduces the uncertainty of measuring procedure and helps you to achieve quick and precise results as well.

  • Aquila Visus CCD Camera System for Vickers Measurement Analysis

    Aquila Visus CCD Camera System for Vickers Measurement Analysis

    CCD camera system for Vickers hardness and indentation analysis. Have your Vickers hardness tests conducted and analysed with variable statistical functions offered by the Aquila Visus measurement analysis software. The digital analysis significantly reduces the uncertainty of measuring procedure and helps you to achieve quick and precise results as well.

  • You see: 1-16 / 16 items
    Show per page
    Sort:
    Top